Observation:

In the cooling cycle, a heat pump is just a conventional air conditioner. For a detailed explanation and a visual sequence of events for a cooling cycle, click here to see our web page "How Does A Split System Air Conditioner Work?"

Theory:

In the heating cycle, the “brain” of a heat pump (the reversing valve) reverses the flow of the refrigerant. Now the refrigerant, instead of extracting heat from within the structure and expelling it outside, extracts heat from the outside and brings it inside.
Heat can be extracted from the outdoor air as long as the temperature of the refrigerant in the outdoor coil is lower than the temperature of the outdoor air. When the outdoor air temperature is 0 degree Fahrenheit it still contains 90% of the heat which it contained at 70 degree Fahrenheit.

A Visual Sequence Of Events Of The Heating Cycle Follows:

Thermostat (1st stage)* (1) simultaneously energizes indoor blower (10), outdoor condenser fan (5), and compressor (3). Refrigerant (2) enters compressor (3) as a low temperature (LT), low pressure (LP) gas. Compressor’s (3) “squeezing” action converts LT/LP gas to high temperature (HT), high pressure (HP) gas (7) as it leaves compressor (4) and enters the indoor coil (8). Indoor Blower (10) causes transfer of heat from this HT/HP gas as it circulates return air (9) over the indoor coil (8). As the HT/HP gas loses its heat to the air surrounding the indoor coil, it is reduced to a HP/LT liquid. HP/LT liquid leaves the indoor coil (8) and enters the outdoor coil (4) through a narrow orifice (expansion valve), it literally “boils off” causing it to lose pressure and again becoming a LT/LP gas. This LT/LP gas, flowing through the outdoor coil (4), absorbs heat from the outside air (6) circulated over the outdoor coil by the condenser fan (5) and returns to the compressor (3) to begin a new cycle.


* A heat pump is most efficient at temperatures above 32 degrees (often called the “balancing point”). When the house requires more heat than can be extracted from outside air below the balancing point, electric strip heaters (2nd stage), usually built into the air handler, are energized by the thermostat.

NOTE: Occasionally, heat pumps must remove the frost that forms on the outdoor condenser coil. By going into a “defrost cycle”, heat pumps automatically rid themselves of the frost by switching from heating to cooling for a few minutes to melt this frost. The resulting “steam” that comes from the top of the condenser, accompanied by the sound of the reversing valve, sometimes alarms homeowners unfamiliar with the process.

If you find an error on this page I would appreciate it if you would email us or call (757) 600-0422.

Our Customers Say It Best

  • “Climatemakers did the complete 40 point tune-up they advertised.”

    G. Smith

  • “Your people are the best.”

    D. Ray

  • “We love our new a/c.”

    J. Jones

  • “I am very satisfied.”

    S. Wetmore

  • “We had nothing but a good experience with your company.”

    S & R Burkhead

  • “I will continue to use and recommend your service for the foreseeable future.”

    R. Koch

  • “Always been satisfied with your products and workmanship.”

    B. Crutsinger

  • “heat pump check up”

    Walt

  • “They are good, organized wonderful workers.”

    L. Tolentino

  • “Everything was great.”

    R. Brock

  • “Reasonable Pricing, Efficient Istallation and Professional Service- I highly recommend!”

    Renee

  • “We are very impressed that you would stand by your product and installation 8 years after the initial installation.”

    J. & J. Gordon

  • “Both were attentive to detail and show professional training habits.”

    T. Medlin

  • “Professional, prompt, courteous & respectful at all times.”

    R. DeJaegher

  • “I am pleased to know that I can depend on Climatemakers!”

    C. Giesinger

Great Service Is Our Mission

Total Indoor Comfort Starts With Climatemakers
  • Available 365 Days / Year For Your Convenience

  • Seasonal Promotions & Financing Available Year Round

  • Trane Comfort Specialists & Servicing All Brands

  • 65 Years Experience & Backed by Warranties

  • Trained & Licensed Techs Fix It Right The 1st Time

  • Courteous and Knowledgeable Office Staff

  • Using Only the Best Equipment & Tools

  • Careful of Your Home - We Keep You Clean & Comfortable